欢迎来到装配图网! | 帮助中心 装配图网zhuangpeitu.com!
装配图网
ImageVerifierCode 换一换
首页 装配图网 > 资源分类 > PPTX文档下载
 

BioCascadeIncCleanAirandWaterSystems生物栅公司清洁的空气和水系统PPT学习课件

  • 资源ID:23968671       资源大小:5.81MB        全文页数:22页
  • 资源格式: PPTX        下载积分:20积分
快捷下载 游客一键下载
会员登录下载
微信登录下载
三方登录下载: 微信开放平台登录 支付宝登录   QQ登录   微博登录  
二维码
微信扫一扫登录
下载资源需要20积分
邮箱/手机:
温馨提示:
用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)
支付方式: 支付宝    微信支付   
验证码:   换一换

 
账号:
密码:
验证码:   换一换
  忘记密码?
    
友情提示
2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

BioCascadeIncCleanAirandWaterSystems生物栅公司清洁的空气和水系统PPT学习课件

Page 1 of 20 Air Principal engineer of the bio-hygienic products offered by the company Nutley, New Jersey; Company headquar ters, manufacturing operations and technical research center Page 2 of 20 How CAP/CWP works Living organisms obtain energy by oxidation reactions. Humans and animals consume food therefore capturing the energy from the food source and reducing it to carbon dioxide,water and solids.Biological Oxidation Page 3 of 20 Biological Oxidation is a natural reaction where micro-organisms capture the energy in an organic substance (food source) and use it for the oxidation process.This allows biological oxidation to take place without a large increase in temperature or energy usage. The results of this are CO2, water and inert bio-solids.As contaminants come in contact with micro-organisms, they are biologically oxidized to CO2 and water. Heavy metals and solids are consolidated and rendered harmless. Source: Biological Oxidation (continued) Page 4 of 20 Bio-hygienicsContaminants and odors that are persistent travel on particulates. Most large particles will travel with air flow and can be vented.Small particles, the ones which are most harmful, are resistant to normal air flow and cannot be vented. These particulates are electrically charged. Their motion is controlled by electrical fields not by air flow. For these reasons, many odors linger even when an area is exhausted.(bio-hi jenikx); The application of compact treatment plants utilizing bio-oxidation for indoor and outdoor applications Page 5 of 20 CAP neutralize contaminants in the air and creates an electrically neutral “clean zone.” Contaminants, both positively and negatively charged, are attracted to this neutral clean zone, where they are captured in the unit and biologically oxidized.CWP work the same way, creating a clean water zone. Contaminants move to the clean zone, are drawn into the unit, where they are biologically oxidized. Bio-hygienics (continued) Page 6 of 20 Substantial cost savings Superior technology to Carbon - substantially more economical Thermal destruction First bio-oxidizer designed for indoor applications Miniaturized plants save energy and space Single technology, single solution Very low maintenance Can be installed modularly to meet growing demands Bio-hygienics offers the benefits of immobilized cell technology in a compact treatment plant that is fast,effective and economical. Advances in bio-hygienics address air and water quality, nuisance odor issues and industrial waste management in a complete, economical solution for companies large and small. CAPs and CWPs are the only bio-systems that address air and water contaminants bio-hygienically. Page 7 of 20 Machine OperationThe CAP Machine is can be modified to fit both stationary and portable applications. The size of the machine is based on both area covered and amount of pollution presentPortable applications: It is recommended the machine be in operation in the area prior to activity related to targeted pollution Page 8 of 20 BioOX is the Bio-Enzyme microbial media used to consume pollution. Start up recommendations and amount used during normal operation are based on machine and application. (Chart to come later in presentation). The more pollution ,the more BioOx needed. Many applications will need less BioOx the longer the machine has been operating as it will clean the air and built up pollution in walls, ceiling tiles and ventilation systems. Page 9 of 20 CAP/CWP Dual outlet power supply to run pump and fan.Water must be added as needed(daily in most cases). Automatic water feed can be installed on larger machines.Heaters can be added for exterior applications to prevent water freeze.BioOx added monthly or more frequently as needed.CAP requirements for normal operation Page 10 of 20 Trash Transfer Station Applications CAP 5000 with Rodent Intake Guards CAP 5000 Page 11 of 20 Can be made portableWill cover up to 3,000 sq.ft.10 lbs. of pollution per dayCAP 90 Page 12 of 20 CAP 600 Covers areas over 5,000 sq.ft.Destroys up to 60 lbs. of pollution per dayInterior and exterior applications Page 13 of 20 Compare Indoor Air CleanersType Cleaner Gases VOCS Particulates Bio-Hygienics SafetyOzone Ionizer UV HEPA (all air filters) Carbon Canister CAP Technology Evaluation Table for Indoor Air Cleaners Page 14 of 20 CAP Machine SpecificationsModel Equiv. Flow Rate (cfm) Pollution Destruction (lbs/day)* BioOx Usage Size & Weight (US) Power Consumption Area Model Cleans Typical ApplicationNEW CAP-50 500 5 8 oz startup2 oz/week for 2 mos.Thereafter 2 oz/month 12” sq x 15”18 lbs30 W Up to 800 ft2 Room, officeNEW CAP-75 520 7 8 oz startup4 oz/week for 2 mos.Thereafter 4 oz/month 12” sq x 20”20 lbs30 W Up to 1500 ft 2 Small house, officeNEW CAP-80 1000 10 16 oz startup4 oz/week for 2 mos.Thereafter 4 oz/month 12” sq x 24”25 lbs30 W Up to 2000 ft2 Medium office, garage, shop, salon, schoolroomCAP-90 Industrial Model 1000 10 16 oz startup4 oz/week for 2 mos.Thereafter 4 oz/month 15” sq x 32”35 lbs40 W Up to 3000 ft2 Office, plant, garage, commercial & small industry Page 15 of 20 CAP Machine Specifications (continued)Model Equiv. Flow Rate (cfm) Pollution Destruction (lbs/day)* BioOx Usage Size & Weight (US) Power Consumption Area Model Cleans Typical ApplicationCAP-600 7500 60 1 gal. startup16 oz/week for 2 mos.Thereafter 16 oz/month 30” dia x 48”26” at base200 lbs175 W Units designed to handle commercial and industrial areas of 5000 ft 2 and larger, with heavy pollution load Small-medium industry, plant, warehouse, lab, loading dock, restaurant, bar, hotel, parking garageCAP-2500 12500 250 2 gal. startup48 oz/week for 2 mos.Thereafter 48 oz/month 36” dia x 50”+ 12-24” fan housing300 lbs 438 W Industry, plant, terminal, indoor/outdoor, heavy pollutionCAP-5000 19400 500 3 gal. startup gal./week for 2 mos.Thereafter 64 oz/month 52” dia x 50”+ 12-24” fan housing500 lbs 500 WCAP-X Series (all models above) All environments. Specifically designed for extremely concentrated and toxic air contaminants Concentrated discharges from mixers, reactors and other similar equipment Page 16 of 20 CWP Machine SpecificationsModel Equiv. Flow Rate (gpm) Pollution Destruction (lbs/day)* BioOx Usage Size & Weight (US) Power Consumption Area Model Cleans Typical ApplicationCWP-100 2 10 4 oz./mo.Startup: 16 oz. Then 4 oz/week for 2 mos. 12” sq x 20”30 lbs Small, compact and portable For sinks, fish tanks, ponds. Small space applicationsCWP-175 20 40 16 oz/mo.Startup: 32 oz. Then 8 oz/week for 2 mos. 12” sq x 20”20 lbs 30 W Small-scale industry, industrial wastewater, waste tank contents, fuel-contaminated home sumps or direct treatment of ground waterCWP-SVE 20-50 60 16 oz/mo.Startup: 1 gal. Then 16 oz/week for 2 mos. 30” dia x 8”100 lbs Saves on carbon costs For industrial applications, fish tanks, wells, ponds, small lakes. Page 17 of 20 CWP Machine Specifications (cont.)Model Equiv. Flow Rate (gpm) Pollution Destruction (lbs/day)* BioOx Usage Size & Weight (US) Power Consumption Area Model Cleans Typical ApplicationCWP-1000 50 100 24 oz./mo.Startup: 1 gal.Then 24 oz/week for 2 mos. 36” dia x 48”250 lbs. Cleans large amounts of liquid.Designed for sudden increase in flow. Wastewater, chemical waste streams, waste tank contents.Large volume streams or surface water runoff.Direct treatment of groundwater.CWP-2500 50-100 250 48 oz./mo.Startup: 2 gal.Then 48 oz/week for 2 mos. 36” dia x 50”250 lbs.CWP-5000 100-200 500 64 oz./mo.Startup: 3 gal.Then gal./week for 2 mos. 52” dia x 50”350 lbs.CWP-25000 100-500 2500 2.5 gal./mo.Startup: 10gal.Then 1 gal./week for 2 mos. 72” dia x 84”600 lbs. Page 18 of 20 For more information or to contact us:www.Bio-C Page 19 of 20 BioOX is the Bio-Enzyme microbial media used to consume pollution. Start up recommendations and amount used during normal operation are based on machine and application. (Chart to come later in presentation). The more pollution ,the more BioOx needed. Many applications will need less BioOx the longer the machine has been operating as it will clean the air and built up pollution in walls, ceiling tiles and ventilation systems. Page 20 of 20 CAP/CWP CAP 600 Covers areas over 5,000 sq.ft.Destroys up to 60 lbs. of pollution per dayInterior and exterior applications Page 21 of 20 CWP Machine Specifications (cont.)Model Equiv. Flow Rate (gpm) Pollution Destruction (lbs/day)* BioOx Usage Size & Weight (US) Power Consumption Area Model Cleans Typical ApplicationCWP-1000 50 100 24 oz./mo.Startup: 1 gal.Then 24 oz/week for 2 mos. 36” dia x 48”250 lbs. Cleans large amounts of liquid.Designed for sudden increase in flow. Wastewater, chemical waste streams, waste tank contents.Large volume streams or surface water runoff.Direct treatment of groundwater.CWP-2500 50-100 250 48 oz./mo.Startup: 2 gal.Then 48 oz/week for 2 mos. 36” dia x 50”250 lbs.CWP-5000 100-200 500 64 oz./mo.Startup: 3 gal.Then gal./week for 2 mos. 52” dia x 50”350 lbs.CWP-25000 100-500 2500 2.5 gal./mo.Startup: 10gal.Then 1 gal./week for 2 mos. 72” dia x 84”600 lbs. Page 22 of 20

注意事项

本文(BioCascadeIncCleanAirandWaterSystems生物栅公司清洁的空气和水系统PPT学习课件)为本站会员(可****)主动上传,装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知装配图网(点击联系客服),我们立即给予删除!

温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!