欢迎来到装配图网! | 帮助中心 装配图网zhuangpeitu.com!
装配图网
ImageVerifierCode 换一换
首页 装配图网 > 资源分类 > DOCX文档下载
 

西南交通大学基础工程课程设计

  • 资源ID:229366890       资源大小:433.23KB        全文页数:13页
  • 资源格式: DOCX        下载积分:15积分
快捷下载 游客一键下载
会员登录下载
微信登录下载
三方登录下载: 微信开放平台登录 支付宝登录   QQ登录   微博登录  
二维码
微信扫一扫登录
下载资源需要15积分
邮箱/手机:
温馨提示:
用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)
支付方式: 支付宝    微信支付   
验证码:   换一换

 
账号:
密码:
验证码:   换一换
  忘记密码?
    
友情提示
2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

西南交通大学基础工程课程设计

Foundation Design姓名 马 德 林 学号 20100193 班级 2010级土木茅1班 西南交通高校土木工程学院2013年5月CONTENTSProblem-2Design-4 Chapter one Unit conversion-4 Chapter two Design load calculation-4 Chapter three Geotechnical designing-4 Step 1 to Step 9 Allowable bearing pressure method-4 Step 10 Checking moment load-8 Chapter four Structural designing-8 Part A Determine required thickness based on a two-way shear analysis-8 Check one-way shear-9 Part B Design the flexural steel-9 Chapter five Sketch of the designed footing-11 Figure 2 Thickness and effective depth-11 Figure 3 Dimensions and reinforcing steel-11 Figure 4 Inner block and outer block-12 Figure 5 Structural show-12Problem:Design for Practice A proposed office building is to be constructed at the site with a geologic pro in figure 1. The ground table is at 5.5 ft. The shallow strata are very soft. The data for these strata maybe used in foundation design were obtained from a series in-situ tests and laboratory tests, and showed in table 1. In the table, Su is undrained shear strength; is preconsolidation stress. Medium Sand (Dr=60%)0-ft12-ft23-ft27-ftGWT 5.5-ftHigh Plastic Clay (CH)Silty Clay (CL)Very Stiff Silty Clay (CL)Fig. 1 geologic section for the construction siteThe design columns of the proposed office building will carry the following loads: dead vertical load range 30-100 k, live vertical load range 20-75 k, and dead load moment range 0-50 ft-k. These columns are to be supported on spreading footings. A sketch of an interior column and its spreading footing is given in figure 2. If such an interior carrying a 50k dead vertical load, a 50k live vertical load, and a dead load moment 20 ft-k. Try to determine the spreading footing of this column. The design task should including followings,Table 1 data for different strata(ft)(1) Unit conversionBefore beginning your design, please convert the data in the figures and tables from English to SI, and please use SI in your designing.(2) Design load calculationThere are two methods of expressing and working with design loads: the allowable stress design (ASD) and resistance factor design (LRFD). Calculate both of them.(3) Geotechnical designingSelect a suitable type of the spreading footing, determine the footing depth, determine allowable bearing pressure, and determine the required base dimensions for the footings of the column in Figure 2.Fig. 2 A sketch of the typical interior column and its footing(4) Structural designingDetermine the materials using in the designed footings, determine the thickness of the footing, and determine the reinforcing steel of the footing.(5) Sketch of the designed footingShow your design in a sketch.A proposed designChapter one Unit conversionTo ConvertTo Multiply byftm0.3048psfkPa0.04787pcfkN/m30.1571Data for different strata (SI)Depth Range(m)SoilDescription0-3.657CH16.49561.2740.150.02124.462CL17.59586.1660.110.015143.610Med.Sand18.852-0.0060.002->8.229CL18.538124.4620.080.01287.220Tips: to convenient, English units will be used in the designing.Chapter two Design load calculationThe allowable stress design (ASD): ( ) ()Resistance factor design (LRFD): Chapter three Geotechnical designingStep 1- per TABLE 8.1 () Use an estimated D of 2 ft (24 in)Step 2- The groundwater table is at 5.5 ft ,and is not a concern at this siteStep 3- per Figure 6.11 (Soil Type: Clay Design F with Typical Range) Use F=3.5step 4- For high clay, if saturated undrained conditions exist( as same as the problem statement), we may conduct a stress analysis with the shear strength defined as and . In this case, (per TABLE 6.1) Hence,. Using square foundation(B=L). Using the BEARING.XLS spreadsheet with ,the computed allowable bearing pressure, Step 5- per TABLE 2.2 ( Typical commercial and residential buildings) Per TABLE2.1 for office building, use ( in order to control differential settlement here)Step 6- using TABLE 7.5 for clayey natural soil,assuming the foundation is a "rigid" structure, the design value of is 0.5Step 7- , so the total settlement requirement controls the settlement analysisStep 8- using classical method to compute total settlement of shallow foundation, which is based on Terzaghi's theory of consolidationBecause of the assumption that all of the soils are over-consolidated, the equation of the total settlement is: Case1(): Case 2(): Where :=rigidity factor (per TABLE 7.1, for spread footings, )=initial vertical effective stress at midpoint of the soil layer=final vertical effective stress at midpoint of the soil layer and could be computed by simplified method equation: (for square foundation) In which , =bearing pressure =depth from bottom of foundation to point =vertical effective stress at a depth D below the ground surface (in this case, )=pre-consolidation stress at midpoint of the soil layer, and Now, we can compute the consolidation settlement after dividing the soil beneath the footing into layers.Figure 1 Dividing the soil beneath the footing into five layersTry with , At midpoint of soil layer(in)LayerNo.H(ft)zf(ft)psfpsfpsfpsfCase3.51.75289129015792889OC-I0.150.020.536.56.7571683715533316OC-I0.150.020.44512.597839913773978OC-I0.110.0150.11618125122114724251OC-I0.110.0150.064231515143165815150C-II0.0060.0020.01= 1.15, so the settlement criterion has not been satisfied.Try with , At midpoint of soil layer(in)LayerNo.H(ft)zf(ft)psfpsfpsfpsfCase3.51.7528997612652889OC-I0.150.020.466.56.7571671114273316OC-I0.150.020.40512.597837513533978OC-I0.110.0150.11618125121614674251OC-I0.110.0150.064231515142165715150C-II0.0060.0020.01= 1.04, so the settlement criterion has not been satisfied.Try with , At midpoint of soil layer(in)LayerNo.H(ft)zf(ft)psfpsfpsfpsfCase3.51.7528986311522889OC-I0.150.020.436.56.7571665713733316OC-I0.150.020.37512.597836313413978OC-I0.110.0150.10618125121314644251OC-I0.110.0150.064231515141165615150C-II0.0060.0020.01= 0.97, so the settlement criterion has been satisfied.(Tips: using the SETTLEMENT.XLS with and can also produce )Step 9- 1078<2770, so the settlement controls the design. Rounding to a multiple of 500 psf gives:For a 100k column load(a 50k dead vertical load and a 50k live vertical load),use Step 10- checking moment loadUsing Equation 5.5:, so OK for eccentric loadingSince (in practical engineering, 5% error is allowed), this design is satisfactory.Hence, a suitable type of the spreading footing may be chosen as:The footing depth: Allowable bearing pressure: Base dimension for the footing: (square foundation)Chapter four Structural designing Now, a 21-inch square reinforced concrete column(c=21in) carries a vertical dead load of 50k, a vertical live load of 50k, and a dead load moment 20 ft-k( that's to say, , ). Because of the small applied load and inspection costs of high strength concrete, we will use and .Part A- Determine required thickness based on a two-way shear analysis:Try T=12 in: Not acceptable!Try T=15 in: OK! However, moment load is present here, one-way shear needs to be checked, too.Check one-way shear, using Equation 9.8: Using Equation 9.9: OK! Therefore, T=15 in; d=11 in.Part B- Design the flexural steel Find the required steel area Check minimum steel (for grade 60 steel)Use Use 7 #7 bars each way ()(Tips: The final value of (#7 bars) is determined as a part of the flexural analysis, and is different from 1 in assumed before. However, this difference is small compared to the construction tolerances, so there is no need to repeat the shear analysis with revised .) and Acceptable! Clear space between bars=144/8-0.875=17 in< 3T=45 in or 18 in () Check development lengthFor spread footings, use , which is conservation.c=spacing or cover dimension=3+0.875/2=3.44 in=reinforcement location factor=1.0 for all other cases=coating factor=1.0 for uncoated bars=reinforcement factor=1.0 for #7 and larger bars=lightweight concrete factor=1.0 for normal concrete use 2.5,so the development length is OK.(Tips: It's easy to compute that using 9#6 bars each way () is also acceptable.) To sum up, the spread footing structure can be designed as:Materials:Concrete: Reinforcing steel: grade 60 steel () 7 #7bars each way ( )Structure:The footing thickness: effective depth: Chapter five Sketch of the designed footingFigure 2 Thickness and effective depth Figure 3 Dimensions and reinforcing steelFigure 4 Inner block and outer blockFigure 5 Structural show

注意事项

本文(西南交通大学基础工程课程设计)为本站会员(hh****2)主动上传,装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知装配图网(点击联系客服),我们立即给予删除!

温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!