姚斌-机电控制技术-考试试卷及答案解析
《姚斌-机电控制技术-考试试卷及答案解析》由会员分享,可在线阅读,更多相关《姚斌-机电控制技术-考试试卷及答案解析(16页珍藏版)》请在装配图网上搜索。
1、精选优质文档-倾情为你奉上Mechatronic Control SystemsSpring 2013Dr. Bin YaoFINAL EXAM April 30, 2013ProblemPoint ValuePoints Gained120220340420Total100INSTRUCTIONS: 1. This is a Closed book exam. You are allowed one help sheet of hand-written summary.2. Your exams must be stapled.3. Circle your final answers.4.
2、Be neat and clear. PROBLEM 1 (20Points)Consider the following feedback system: Y(s)-ControllerPlantwhere.You are required to design a controller to meet the following performance specifications: (P1). Zero steady-state error for ramp type reference input and constant disturbance (P2). The resulting
3、closed-loop system should not have excessive transient responses for step reference input , i.e., your design should avoid either excessive large overshoot or large undershoot in the step responses. To solve this problem, you are required to follow the following procedure:a) Determine the correct co
4、ntroller structure that is needed to meet the performance requirement P1. To receive full credit, you need to justify your answer as well.b) Determine the suitable desired pole locations of the closed-loop system so that the performance requirement P2 can be satisfied. Again, to receive full credit,
5、 you need to justify your answer as well.c) Determine the unknown controller parameters to meet the above performance requirements. Solutions:由上面两条定理可以得到结论:1、a). As the plant has an integrator, to satisfy (P1), the controller only needs one integrator, i.e., (1)With the controller (1), the closed-lo
6、op output is given by (2)Thus, for ramp type reference input (i.e., ) and constant disturbance (i.e., ), the system output tracking error is (3)So as long as the CL system is stable (i.e., the denominator in (3) has all roots in LHP), the condition for applying FVT is satisfied. By FVT, you can easi
7、ly show that the steady-state error in (3) is zero.PROBLEM 1 (conts)b). As the plant has an unstable pole at 1, to avoid excessive overshoot due to this unstable pole, the CL bandwidth should be higher than the break frequency of this unstable pole, which can be roughly met by imposing the following
8、 conditions on dominant CL poles:(4)As the plant has a stable zero at -3 which tends to increase the overshoot significantly when it is slower comparing to the CL bandwidth, to avoid excessive overshoot, the following condition on dominant CL poles should be imposed normally:(5)Thus we can place the
9、 dominant CL poles around 2 to make a compromise between the conflicting requirements of (4) and (5). Note that as this zero is stable, you can also cancel this zero in the controller design (by placing one CL pole at -3) to remove its effect on the CL response with respect to the reference input as
10、 well. In that case, its effect still appears in the CLTF from the disturbance input to the output. c). With a second-order controller of the form (1), (6)we have four controller parameters free to choose and the resulting CL system has four poles. Thus we can arbitrarily place all four CL poles wit
11、h the controller form of (6). For simplicity, let all CL poles at -2, which leads to the following desired CL characteristic polynomial (CLCP): (7)From (2), the actual CLCP with the controller (6) is (8)Comparing (7) and (8), we obtain (9)Thus, (10)PROBLEM 2 (20 Points)Consider the following two-DOF
12、 feedback system: SensorReference ValueNoises-ControllerPlantFig.2.1where and the system has the following characteristics: (C1) The input disturbance has significant energy in the frequency band 0, 1 rad/s.(C2) The measurement noise has significant energy in the frequency band 5, 100rad/s.(C3) The
13、reference signal has significant energy in the frequency band 0, 10 rad/s.You are required to synthesize proper controller transfer functions and to meet the following specific design goals while taking into account the above system characteristics: (P1) Zero steady-state errors for ramp type output
14、 disturbances (P2) The response of the closed-loop system for step reference input has no oscillations.(P3) The closed-loop system should follow the reference signal well in the frequency band specified in (C3). To solve this problem, you may want to follow the following procedure:a) Determine the c
15、orrect structure of feedback controller that is needed to meet the steady-state performance requirement P1. b) Determine the suitable desired pole locations of the closed-loop system that take into account the system characteristics (C1)-(C3). To receive full credit, you need to justify your answer
16、as well.c) Determine the parameters of the feedback controller to place the closed-loop poles at the desired locations.d) Determine a suitable filter transfer function so that (P2) and (P3) are satisfied. Solutions:a). As the plant has an integrator, to satisfy (P1), the controller only needs one in
17、tegrator, i.e., (1)b). (C1) demands that the CL bandwidth should be at least higher than 1 rad/s to have certain attenuation to the input disturbance in the frequency band of 0, 1 rad/s. (C2) implies that the CL bandwidth should not be set too high to amplify the effect of noise in the frequency ban
18、d of 5, 100 rad/s. Thus a good compromise for the CL bandwidth to meet both requirements should be around 2 to 3 rad/s. So assume that we would like to place dominant CL poles at -3 in the following. c). With a first-order controller of the form (C1) (2)there will be two controller parameters free t
19、o choose and the resulting CL system will be of order 2. Thus we can arbitrarily place the two CL poles. With , the desired CLCP is(3)The actual CLCP with the controller (2) is (4)Comparing (3) and (4), we obtain (5)d). With the controller (5), the CLTF from to is (6)Thus, to be able to track refere
20、nce signal in the frequency band of 0, 10 rad/s, a feedforward TF is needed so that the resulting CLTF from to has a bandwidth far more than 10 rad/s. As such, we needs to cancel the slow CL poles at -3 in (6). Furthermore, to avoid overshoot, the stable zero in (6) should be cancelled as well. With
21、 all these in mind, we can choose (7)where is the small time constant of the additional filter needed to make proper.Problem 3 (40 Points)Consider the control of an inertia load such as the rigid ECP emulator introduced in the lectures and the homework. In the presence of disturbance forces such as
22、the Coulomb friction force, the inertia load dynamics can be described by: where represents the disturbance force. Assume that the disturbance force is constant but unknown (i.e., =unknown constant), and only the output is measured. a) Design a minimum-order observer to estimate the unmeasured state
23、 (i.e., the velocity) and the unknown constant disturbance force. The observer gain should be chosen to place all observer poles at -5.b) Consider the following output feedback control law with disturbance estimate:where and represent the plant state and disturbance estimates from part a), and repre
24、sents the filtered reference input. Determine the feedback gain so that all un-cancelled poles of the closed-loop transfer function from the filtered reference input to the output, i.e., , are at -1.c) Draw the equivalent block diagram of the closed-loop system with the above controller and estimato
25、r using transfer functions. To receive full credit, you need to obtain the explicit expressions of all relevant transfer functions.d) Obtain the closed-loop transfer function from the filter reference input to the output, and verify that all its un-cancelled poles are at -1 as required.e) Obtain the
26、 closed-loop transfer function from the disturbance input to the output, . Use this transfer function to show that constant disturbances will not cause any steady-state error in the output as expected. Solutions:a) . 降阶观测器极点配置的方法For constant disturbance , the augmented system model is (1)which is in
27、 the standard form for designing minimum-order observer with and (2)The observer gain matrix can then be determined by placing the eigenvalues of (3)at -5, i.e., (4)(5)The minimum-order observer is thus given by(6)b). 状态反馈极点配置的求法 :根据独立性原则,状态观测器和状态反馈互不影响,也就是K和L互不影响The closed-loop poles due to the sta
28、te feedback gain are determined by (7)Thus, to have the un-cancelled CL poles at -1, (8)c). With the minimum-order observer (6), the control law is given by (9)Substituting (9) into (6), (10)Thus,(11)and the control law (9) in s-domain is given by (12)The equivalent block diagram of the above CL sys
29、tem can then be drawn below:图中从u+d到Y的输出是由原系统中的A、B、C矩阵求出来的!orFig.1d). From Fig.1, the CLTF from to is (13)which has all uncancelled poles at -1.e). From Fig.1, the CLTF from to is (14)which has a in the numerator. As such, , indicating that the constant disturbances will not cause steady-state error.
30、Problem 4 (20 Points)Consider the same second-order system as in Problem 3 but with an input disturbance, i.e.,where represents the disturbance force. Assume that the disturbance force is constant but unknown (i.e., =unknown constant), and only the output is measured. Design an output feedback contr
31、oller using the technique of state-estimator with disturbance estimation and compensation (i.e., ) to achieve the following performance requirement:a) Stable closed-loop system.b) Zero state-steady error for any constant input disturbance .c) All the un-cancelled poles of the closed-loop transfer fu
32、nction from the filtered reference input to the output, i.e., , are at -2.d) All other assignable closed-loop poles should be placed at -10. Solutions 1:As shown in Problem 3, the given system is not observable but detectable, and is not controllable but stabilizable. By introducing the coordinate t
33、ransformation of (a1)The system matrices in the new coordinate are (a2)which isolates the uncontrollable and unobservable mode represented by the coordinate . Though this mode cannot be moved with any state feedback and observable design, it is stable and does not contribute to the overall TF from t
34、he input to the output. Thus we can ignore this mode and only consider the controllable and the observable mode in synthesizing the output feedback controller. Thus the given system is reduced to(a3)For constant disturbance , the augmented system model is (a4)A full-order observer can then used to e
35、stimate the augmented states in (a4). The observer gain matrix should be chosen such that the eigenvalues of (a5)are at -10, -10, i.e., (a6)(a7)With the above observer gain, a full-order observer can be constructed as (a8)To have the CL poles by the state feedback at -2, from (a3), the state feedbac
36、k gain for should be chosen as (忽略Z1,因为不可观) (a9)With the observer (a8) and the above gain in (a9), the following stabilizing output feedback control law can be used: (a10)Solutions 2:For constant disturbance , the augmented system model is (1)As shown in Problem 3, the above system is not observable
37、 but detectable, which means that we cannot move the unobservable mode with any observable designs but we still can design a stable state observer. So when a full-order observer is used to estimate the augmented states in (1), we can arbitrarily place the other two observer CL poles while the third
38、one should be at -1. Thus, the observer gain matrix should be chosen such that the eigenvalues of (3)are at -10, -10, and -1, i.e., (4)(5)The fact that there are infinite number of solutions to the observer gains is due to the appearance of unobservable mode. With the observer gains satisfying (5),
39、a stable full-order observer can be constructed as (6)where can be any value. Again, as shown in Problem 3, the given system is not controllable but stabilizable with the uncontrollable mode given by . Thus, we cannot use state feedback to move the uncontrollable mode . The state feedback gain shoul
40、d thus be chosen such that the eigenvalues of (7)at -1 and -2 as required, which leads to (8)Again, the non-unique solution to is due to the appearance of uncontrollable mode. With the observer (6) and the gain in (8), the following stabilizing output feedback control law can be used: (9)where can be any value. 专心-专注-专业
- 温馨提示:
1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
2: 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
3.本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 前导课-金融计算器的使用参考资料课件
- 新人教部编版小学语文一年级下册《咕咚》PPT课件
- 新人教版小学三年级数学下册:第三单元《复式统计表》ppt课件
- 喂出来讲授版本详解课件
- 新人教版一年级数学下册认识人民币简单的计算ppt课件
- 新人教版一年级数学下册《分类与整理》优质课ppt课件
- 新人教版语文一年级下册《夜色》ppt课件
- 喀蔚波医用物理学课件06章直流电
- 新人教版小学数学五年级下册运用最小公倍数知识解决实际问题ppt课件
- 喂养困难的家庭干预教学课件
- 新人教版一年级数学下册期末复习 ppt课件
- 新人教版五年级下册《通分》ppt课件
- 喀斯特地貌(地质地貌)课件
- 啤酒音乐季活动概念方案教学课件
- 新人教版四年级下册数学三角形的内角和ppt课件