节能建筑案例研究
![节能建筑案例研究_第1页](https://file4.zhuangpeitu.com/fileroot4/2022-3/25/74a482ee-5e4f-466b-9435-b9020009000c/74a482ee-5e4f-466b-9435-b9020009000c1.gif)
![节能建筑案例研究_第2页](/images/s.gif)
![节能建筑案例研究_第3页](/images/s.gif)
《节能建筑案例研究》由会员分享,可在线阅读,更多相关《节能建筑案例研究(24页珍藏版)》请在装配图网上搜索。
1、建建 筑筑 物物 理理授课班级:授课班级:授课时间:授课时间:2013-20142013-2014学年第学年第 1 1 学期学期主讲教师:罗玲玲主讲教师:罗玲玲案例研究案例研究Kingspan lighthouseThe Code for Sustainable Homes Route Map 案例研究案例研究Kingspan lighthouseThe Code for Sustainable Homes is a set of sustainable design principles covering performance in nine key areas:Energy and CO
2、2WaterMaterials Surface water run-offWastePollution Heath and well beingManagementEcology案例研究案例研究Kingspan lighthouseEnvironmental issues covered by the Code:Environmental Impact CategoriesNumber of CreditsEnvironmental WeightingFactor(as%of total possible Points Score available)Category 1?Energy/CO2
3、 29 credits 36.4%Category 2?Water 6 credits 9.0%Category 3?Materials 24 credits 7.2%Category 4?Surface Water Run-off 4 credits 2.2%Category 5?Waste 7 credits 6.4%Category 6?Pollution 4 credits 2.8%Category 7?Health&Well being12 credits 14.0%Category 8?Management 9 credits 10.0%Category 9?Ecology 9 c
4、redits 12.0%Total 104 credits100.00%案例研究案例研究Kingspan lighthouseLevel 136 Points(Mandatory+33.3 Points)Exceeds Regulations EcoHomes 2006 Pass EST Good Practice Level 2 48 Points(Mandatory+43.0 Points)EcoHomes 2006-Good Level 357 Points(Mandatory+46.7 Points)EcoHomes 2006 Very Good EST Best Practice C
5、onventional Water fittings Level 468 Points(Mandatory+54.1 Points)Greywater/Rainwater Passive House(approx)Level 584 Points(Mandatory+60.1 Points)Zero SAP Significant Renewables Level 690 Points(Mandatory+64.9 Points)Zero Operational Carbon Most Code Credits achieved For Level 6-Mandatory issues:案例研
6、究案例研究Kingspan lighthouseFor Level 6-Mandatory issues:Energy Net-Carbon Zero in operation Very high building envelope thermal performance HLP=0.8 W/mK or greater(SAP)Renewables for all heating,hot water,lights,fans and pumps.Renewables for occupant systems and appliances Credits for other low carbon
7、features Water 80 litres/day per person of potable water On-site water recycling required Using new more stringent Water Calculator 案例研究案例研究Kingspan lighthouseFor Level 6-Mandatory issues:Environmental Impact of Materials Three of five key elements achieve relevant rating of A+to D Update 2007 The G
8、reen Guide Surface water run-off Peak run-off no greater than existing Located in low Flood Risk/Flood mitigation Waste Specified minimum household waste handling Construction waste management system 案例研究案例研究Kingspan lighthouseLighthouse:the Level 6 House案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan l
9、ighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouseTwo different surfaces are demonstrated:BASF PCM(Phase Change Material)plasterboard Dense cement fibre board These surfaces help absorb daytime heat and then give it up to cooler night time purge ventilation.案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse案例研究案例研究Kingspan lighthouse
- 温馨提示:
1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
2: 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
3.本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。